RBF Model for the Mass Loss of a Brass in Cavitation Field

Authors

  • Alina BĂRBULESCU Transilvania University of Brasov, Romania
  • Cristian Ștefan DUMITRIU Transilvania University of Brasov, Romania

DOI:

https://doi.org/10.35219/mms.2021.4.03

Keywords:

brass, cavitation, mass loss, mathematical model

Abstract

This article aims at presenting the model of the mass loss of a brass sample in ultrasonic cavitation field in saline water. The experiments done for data collecting was performed in three scenarios. In the first one, the high frequency generator worked at three power levels - 80 W, at the second one - at 120 W, and in the third one - at 180 W. The Model has been built using the series of the mass loss on surface.

Creative Commons License

Downloads

Download data is not yet available.

Downloads

Published

2021-12-15

Issue

Section

Articles

How to Cite

1.
RBF Model for the Mass Loss of a Brass in Cavitation Field. Ann_UGAL_MMS [Internet]. 2021 Dec. 15 [cited 2026 Nov. 2];44(4):17-21. Available from: https://ojs.ugal.ro/index.php/mms/article/view/4971