X-Ray Diffraction Residual Stress Measurements for Quality Control Testing

Authors

  • Constantin GHEORGHIEŞ "Dunarea de Jos" University of Galati, Romania
  • Alina-Mihaela CANTARAGIU "Dunarea de Jos" University of Galati, Romania
  • Iuliana Valentina STASI "Dunarea de Jos" University of Galati, Romania

Keywords:

XRD, Surface Residual Stress, Grinding, Machining and Shot Peening Processes

Abstract

This paper present the primary difficulties which are associated with the obtaining and interpreting surface X-ray diffraction residual stress results: the surface stresses may be identical for the shoot peening, nitriding and grinding parameters; many machining and grinding metal removal processes can generate local fluctuations in the surface residual stress; for many material removal and surface treatment processes the depth of penetration of the X-ray beam is quite shallow and can cause experimental error in the measurement of the surface stress. The stress distributions by conventional and abusive grinding of 4340 steel, the surface residual stresses for 5160 steel leaf springs shot peened may prohibit the use of non-destructive surface stress measurements.

Creative Commons License

Downloads

Download data is not yet available.

Downloads

Published

2007-05-15

Issue

Section

Articles

How to Cite

1.
X-Ray Diffraction Residual Stress Measurements for Quality Control Testing. Ann_UGAL_MMS [Internet]. 2007 May 15 [cited 2026 Nov. 2];30(1):114-7. Available from: https://ojs.ugal.ro/index.php/mms/article/view/3188

Most read articles by the same author(s)