X-Ray Diffraction Residual Stress Measurements for Quality Control Testing

Autor/innen

  • Constantin GHEORGHIEŞ "Dunarea de Jos" University of Galati, Romania
  • Alina-Mihaela CANTARAGIU "Dunarea de Jos" University of Galati, Romania
  • Iuliana Valentina STASI "Dunarea de Jos" University of Galati, Romania

Schlagwörter:

XRD, Surface Residual Stress, Grinding, Machining and Shot Peening Processes

Abstract

This paper present the primary difficulties which are associated with the obtaining and interpreting surface X-ray diffraction residual stress results: the surface stresses may be identical for the shoot peening, nitriding and grinding parameters; many machining and grinding metal removal processes can generate local fluctuations in the surface residual stress; for many material removal and surface treatment processes the depth of penetration of the X-ray beam is quite shallow and can cause experimental error in the measurement of the surface stress. The stress distributions by conventional and abusive grinding of 4340 steel, the surface residual stresses for 5160 steel leaf springs shot peened may prohibit the use of non-destructive surface stress measurements.

Creative Commons License

Downloads

Download-Daten sind nocht nicht verfügbar.

Veröffentlicht

2007-05-15

Ausgabe

Rubrik

Articles

Zitationsvorschlag

1.
X-Ray Diffraction Residual Stress Measurements for Quality Control Testing. Ann_UGAL_MMS [Internet]. 15. Mai 2007 [zitiert 2. November 2026];30(1):114-7. Verfügbar unter: https://ojs.ugal.ro/index.php/mms/article/view/3188

Am häufigsten gelesenen Artikel dieser/dieses Autor/in

<< < 1 2