Energy dissipation device using fluid dampers

Autor/innen

  • Fănel Șcheaua “Dunarea de Jos“ University of Galati
  • Florin Nedelcuț “Dunarea de Jos“ University of Galati

Schlagwörter:

fluid damper device, viscous damper, seismic isolation, energy dissipation, CFD

Abstract

This scientific paper presents a solution that is adequate for the seismic isolation of small and medium size buildings and bridges. Comprising two seismic isolating devices, the described arrangement is suitable for dissipating an increased level of energy induced to infrastructure by the seism. As other hybrid arrangements, this one uses viscous dampers in order to limit the distance of induced movement of the infrastructure. The internal design of the fluid damper is analyzed using CFD software, to ensure a proper dissipation of the seismic action and to limit its destructive effects.

Veröffentlicht

2012-11-15

Ausgabe

Rubrik

Articles

Zitationsvorschlag

1.
Energy dissipation device using fluid dampers. ANN_UDJG_IM [Internet]. 15. November 2012 [zitiert 2. November 2026];19(2):103-6. Verfügbar unter: https://ojs.ugal.ro/index.php/im/article/view/3742

Am häufigsten gelesenen Artikel dieser/dieses Autor/in

1 2 3 > >>