Long term structural assessment of an FSU ship based on the spectral fatigue method

Auteur/ices

  • George Jagite Bureau Veritas, Bureau Veritas Romania Controle International, Galati
  • Leonard Domnișoru “Dunarea de Jos” University of Galati

Mots-clés :

spectral fatigue method, 3D-FEM model, FSU floating storage unit.

Résumé

For the safety operation of the offshore FSU floating storage units, the structural design must be assessed on the short-term yielding stress criterion and on the long-term fatigue strength criterion. This paper presents the fatigue strength assessment for a large FSU structure with length of 292 m, based on the wave loads from Western North Atlantic at zero speed in the operation area. Besides the waves loading cycles, the oil tanks loading and unloading low cycles are taken into account. The short-term stress analysis is based on a coupled hydrodynamic and structural 3D model. The spectral fatigue analysis is based on the long-term D damage cumulative factor method, considering 100 years as the design exploitation time reference. The numerical results from this study are point out the structural details of the FSU hull which do not comply with the fatigue strength criteria.

Téléchargements

Les données relatives au téléchargement ne sont pas encore disponibles.

Téléchargements

Publiée

2015-12-31

Numéro

Rubrique

Articles

Comment citer

1.
Long term structural assessment of an FSU ship based on the spectral fatigue method. Ann.UDJG.ShipBuilding [Internet]. 31 déc. 2015 [cité 2 nov. 2026];38:99-106. Disponible sur: https://ojs.ugal.ro/index.php/fanship/article/view/1391

Articles les plus lus par le ou les mêmes auteur/ices

1 2 3 4 > >>